Virtual PLCs / Documents / LADV-DS-110

Datasheet · LADV-DS-110

CPU 110 datasheet

CPU 110, LADV100 basic controller: 8 DI, 6 DO, 0 AI, 0 AO, 20 ms fastest scan, ladder and Structured Text.

Download PDFDownload WordRevision 1.0, 1 November 2026

LADV100 basic controller. Order number LV100-C110-14DDT.

DocumentCPU 110 datasheet
CodeLADV-DS-110
Revision1.0, 1 November 2026
FirmwareV1.0.0
Issued byWartens, makers of LADX

Wartens LADV controllers are virtual PLCs that run in a web browser, for learning, for testing logic and for preparing for commissioning. They are not real time, not safety rated, and they cannot control equipment.

Overview

Small fixed-I/O controllers for learning ladder logic. Enough inputs and outputs for a motor station, a set of traffic lights or a garage door, and small enough that every channel is in view.

8 digital in, 6 digital out. The first controller.

Technical data

PropertyValue
SeriesLADV100 Basic
CPUCPU 110
Order numberLV100-C110-14DDT
Variant, as printedDC/DC/DC
Digital inputs8
Digital outputs6
Analog inputs0
Analog outputs0
Expansion slotsNone, fixed I/O
Program memory, ladder64 tags, 32 rungs, 2 routines
Program memory, Structured Text64 variables, 256 statements, 4 program organisation units
Fastest scan20 ms
Watchdog150 ms per scan
Retentive memoryNo. Every start is a cold start
LanguagesLadder (LADX), IEC 61131-3 Structured Text
TasksCyclic and event tasks, priorities from 0, non-preemptive
Online functionsWatch, modify, force I/O, 64-entry diagnostic buffer
Status lampsRUN, STOP, ERROR, MAINT
FirmwareV1.0.0
Serial number, as printedWL26-110-71090
AvailabilityAvailable in the VPLC lab

Addressing

Structured Text names a channel by its IEC 61131-3 direct address. Ladder wires tags to channels in the order the tags are listed.

ChannelsCountStructured Text addresses
Digital inputs8%IX0.0 to %IX0.7
Digital outputs6%QX0.0 to %QX0.5
Analog inputs0none
Analog outputs0none

Status lamps

LampColourMeaning
RUNGreenThe program is executing and outputs are live.
STOPAmberStopped. Outputs are off.
ERRORRedFaulted. Outputs are off until the fault is reset. The diagnostic buffer gives the code.
MAINTAmberAt least one I/O point is forced.

Not included

  • No fieldbus, no network protocols and no physical I/O.
  • No hard real-time guarantee: scans run on simulated time in the browser.
  • No safety rating. Safety functions belong in a safety-rated controller.
  • LADV system manual, LADV-SM
  • Structured Text programming manual, LADV-PM-ST
  • Ladder instruction reference, LADV-IR-LD
  • Diagnostic and fault codes, LADV-DC