Datasheet · LADV-DS-120

CPU 120 datasheet

CPU 120, LADV100 basic controller: 12 DI, 8 DO, 2 AI, 1 AO, 20 ms fastest scan, ladder and Structured Text.

Download PDFDownload WordRevision 1.0, 1 November 2026

LADV100 basic controller. Order number LV100-C120-20DDT-A3.

DocumentCPU 120 datasheet
CodeLADV-DS-120
Revision1.0, 1 November 2026
FirmwareV1.0.0
Issued byWartens, makers of LADX

Wartens LADV controllers are virtual PLCs that run in a web browser, for learning, for testing logic and for preparing for commissioning. They are not real time, not safety rated, and they cannot control equipment.

Overview

Small fixed-I/O controllers for learning ladder logic. Enough inputs and outputs for a motor station, a set of traffic lights or a garage door, and small enough that every channel is in view.

12 digital in, 8 digital out, 2 analog in, 1 analog out.

Technical data

PropertyValue
SeriesLADV100 Basic
CPUCPU 120
Order numberLV100-C120-20DDT-A3
Variant, as printedDC/DC/DC
Digital inputs12
Digital outputs8
Analog inputs2 (INT, 0 to 1000 is 0 to 100 percent)
Analog outputs1 (INT, 0 to 1000 is 0 to 100 percent)
Expansion slotsNone, fixed I/O
Program memory, ladder128 tags, 64 rungs, 4 routines
Program memory, Structured Text128 variables, 512 statements, 8 program organisation units
Fastest scan20 ms
Watchdog150 ms per scan
Retentive memoryYes. A warm restart keeps RETAIN variables, and ladder memory
LanguagesLadder (LADX), IEC 61131-3 Structured Text
TasksCyclic and event tasks, priorities from 0, non-preemptive
Online functionsWatch, modify, force I/O, 64-entry diagnostic buffer
Status lampsRUN, STOP, ERROR, MAINT
FirmwareV1.0.0
Serial number, as printedWL26-120-50280
AvailabilityAvailable in the VPLC lab

Addressing

Structured Text names a channel by its IEC 61131-3 direct address. Ladder wires tags to channels in the order the tags are listed.

ChannelsCountStructured Text addresses
Digital inputs12%IX0.0 to %IX1.3
Digital outputs8%QX0.0 to %QX0.7
Analog inputs2%IW0 to %IW1
Analog outputs1%QW0

Status lamps

LampColourMeaning
RUNGreenThe program is executing and outputs are live.
STOPAmberStopped. Outputs are off.
ERRORRedFaulted. Outputs are off until the fault is reset. The diagnostic buffer gives the code.
MAINTAmberAt least one I/O point is forced.

Not included

  • No fieldbus, no network protocols and no physical I/O.
  • No hard real-time guarantee: scans run on simulated time in the browser.
  • No safety rating. Safety functions belong in a safety-rated controller.
  • LADV system manual, LADV-SM
  • Structured Text programming manual, LADV-PM-ST
  • Ladder instruction reference, LADV-IR-LD
  • Diagnostic and fault codes, LADV-DC